Issued 2026-05-13 19:18
Data refreshed 26 minutes ago · Next refresh: tomorrow 6 AM PT
Weekly Lead Brief · Vancouver

Hvac

Apr 29 – May 13, 2026 · 25 permits match your subscription · 8 new since last week
25
Total leads
8
New this week
$10.4M
Total project value
15
Hot leads >$100k

Map view

Permits in this batch also touch...

Flooring
21
Electrical
18
Plumbing
18
Reno Major
17
New Build
14
Framing
6

This week's permits 25 results · newest first

Issued 2026-05-11 · issued 2 days ago · Permit BP-2024-05151 · New Building
High Density Housing / Commercial - New Building - Building Permit for BP-2024-02016

To construct a 3-storey multiple dwelling building over one level of underground parking with storages, bike storages, and service rooms, having vehicular access from the rear lane.

This is a CP Process Permit and the applicant is Koosha Kheradmandria, P. Eng., CP.

Building to be sprinklered to NFPA 13.

*REVIEWED UNDER VBBL 2019

Refer to Site Permit BP-2024-02016 for all drawings and documents for this site.

Refer to BP-2024-05151 for Building 1
Refer to BP-2024-05152 for Building 2
Refer to BP-2024-05153 for Building 3

STAGED CONSTRUCTION
Stage 3: Full Construction- (2026-05-11- S.Le)
Refer to DPMA DP-2025-00786
Change of Structural Engineer of Record from Damoon Motamedi, Ph.D., P.Eng., from Raft Consulting Ltd., to Yeming Li, P.Eng., Struct.Eng., from Deer Lake Engineering & Associates Ltd. effective November 5th, 2025.
Applicant: Koosha Kheradmandnia DBA: Arvand Engineering
new buildfoundationframingdrywallroofingelectricalplumbinghvac
Issued 2026-04-29 · issued 14 days ago · Permit BP-2025-04275 · New Building
Low Density Housing - New Building - Building Permit for DP-2025-00820 to construct a Multiple Dwelling 'Multiplex' with a three-storey two-unit unit front building, with three parking spaces in the rear building attached carport having vehicular access from the lane.

Note: The entire building to be sprinklered to 2 x NFPA 13D

Note: This is a 3 storey building pursuant to the Zoning and Development By-Law

1.\tHRV proposed – Located in second floor laundry room
2.\tHeat pump proposed – Exterior component located in front and rear patio, Interior component located in third floor closet
3.\tSchedule B: J.H.P. Pao P.Eng (604.972.0115) Structural & Geotechnical
4.\tHPO: Residential Builder- Aqua Homes Development Ltd.


Address Information:

Building 1 (Front) (North)
#1-3114 Graveley St- One Dwelling Unit (north side 1st-3rdfloors)
#2-3114 Graveley St - One Dwelling Unit (south side 1st-3rd floors)

Address and suite numbers assigned as per approved plans for Fire and Emergency response. The address number is to be posted on the building to be visible from the street and the suite numbers are to be posted at the suite entries in accordance with the Building By-law prior to final inspection.

***This permit is issued under the VBBL 2019, with updated energy requirements as per bylaw # 12997 effective Jan 01, 2022.***
Contractor: Aqua Homes Development Ltd · Applicant: QI LI DBA: LQ Design GROUP Ltd
hvacflooringlandscapenew build
Issued 2026-04-29 · issued 14 days ago · Permit BP-2025-04277 · New Building
Low Density Housing - New Building - Building Permit for DP-2025-00820 to construct a Multiple Dwelling 'Multiplex' with a two-storey one-unit rear building with an attached carport providing three parking spaces having vehicular access from the lane.

Note: The entire building, INCLUDING THE ATTACHED CARPORT, to be sprinklered to NFPA 13D (BULLETIN 2024-002-BU)

Note: This is a 2 storey building pursuant to the Zoning and Development By-Law

1.\tHRV proposed – Located in second floor kitchen
2.\tHeat pump proposed – Exterior component located in court yard, Interior component located in main floor mech room
3.\tSchedule B: J.H.P. Pao P.Eng (604.972.0115) Structural & Geotechnical
4.\tHPO: Residential Builder- Aqua Homes Development Ltd.

Address Information:

Building 2 (Rear) (South)
3116 Graveley St- One Dwelling Unit (1st-2nd floors)

Address number assigned as per approved plans for Fire and Emergency response. The address number is to be posted and to the building and to be visible from the street in accordance with the Building By-law prior to final inspection.

***This permit is issued under the VBBL 2019, with updated energy requirements as per bylaw # 12997 effective Jan 01, 2022.***
Contractor: Aqua Homes Development Ltd · Applicant: QI LI DBA: LQ Design GROUP Ltd
hvacflooringnew build